Welcome to our website!

+86-535-8088266      eric.chen@starkinstrument.cn              

Product Catalog
Contact Us
Mobile:+86-18663815259
Tel:+86-535-8088266
QQ:294772396
Email:eric.chen@starkinstrument.cn
Skype:jackie.chan-chemins
Add:No.18 Xiulin Rd, Laishan development zone, Yantai, China.
Whatsapp/Wechat: +86-18663815259

       

Name:26G high frequency radar level transmitter
Model:HBRD902
Measuring range:30m
Accuracy:± 3mm
Working temperature:-40 ~ 150 ℃
Signal output:4~20mA/HART (2/4-wire) RS485/ Modbus
Power supply:DC24V or AC220V

Measuring range: 30 meters

Process connection: thread, flange

Medium temperature: -40 ℃ ~ 150 ℃

Process pressure: -0.1 ~ 4.0MPa

Accuracy: ± 3mm

Protection grade: IP67

Frequency range: 26GHz

Explosion-proof grade:  Exib  CT6 Gb

Signal output: 4~20mA/HART (2/4-wire)

                        RS485/ Modbus



Process connection  Thread: G1½ "A  or 1½"NPT or flange
Antenna materialStainless steel / PTFE
ShellShell sealSilicone rubber
Shell windowPolycarbonate
Ground terminalStainless steel
Power supplyTwo wireStandard(16~26) V DC
Intrinsically safe(21. 6~26. 4) V DC
Power consumptionmax 22. 5mA / 1W
Allow ripple
Flameproof- <100HzUss < lV
- (100~100K) HzUss < l0mV
(22. 8~26. 4) V DC2-wire
(198~242) V AC4-wire  /  110V AC
CableCable entry/plugM20x1.5
Blind block M20x1.5
TerminalsWire cross section 2.5mm²
Output parametersSignal output(4~2 0) mA
Communication protocolHART
Resolution 1. 6μA
Fault signalCurrent output is unchanged
20. 5mA
22mA
3.9mA
Integration time(0~36)s   Adjustable
Blind zoneAntenna end
Max measuring rangeHBRD90110m   (For liquid)
HBRD90230m   (For liquid)
HBRD902T20m   (For liquid)
HBRD90370m   (For solid)
HBRD90480m   (For solid)
HBRD90530m   (For solid)
HBRD90620m   (For liquid)
Frequency26GHz
Communication interfaceHART
Measurement interval>1s (Depending on parameter settings)
Adjust time>1s (Depending on parameter settings)
Display resolution1mm
Working temperature(-40~100) ℃

Process temperature 

(temperature of the antenna section)

HBRD901(-40~130)℃
HBRD902(-40~250)℃
HBRD902T(-40~250)℃
HBRD903(-40~250)℃
HBRD904(-40~250)℃
HBRD905(-40~250)℃
HBRD906(-40~200)℃
Relative humidity˂ 95%
Working pressureMax. 4MPa
ShockproofMechanical vibration 10m/s² , (10~150)Hz



Small antenna size, easy to install ; Non-contact radar, no wear, no pollution.

Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure changes.

Serious dust environment on the high level meter work has little effect.

A shorter wavelength, the reflection of solid surface inclination is better.

Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.

The measuring range is smaller, for a measurement will yield good results.

High signal-to-noise ratio, the level fluctuation state can obtain better performance.

High frequency , measurement of solid and low dielectric constant of the best choice.

The radar sensor is 26G high frequency radar level measurement instrument, the maximum measurement range of up to 70 meters. The antenna is further optimized, signal microprocessor model can be more  high rate analysis, the instrument can be used for reactor, solid silo and some complex measurement conditions.

Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous).

install.jpg

A:Range setting   B: Low level adjustment   C: High level adjustment   D: Blind zone

Temperature resistance, pressure resistance, and slightly corrosive liquid.

Hits: 【Print】