Name:LWGY series liquid turbine flow meter
Model:LWGY
Nominal diameter:DN4~200(mm)
Accuracy:±1%, ±0.5%
Working temperature:-20~+120 ℃
Signal output:4~20mA
Protection:IP65

Nominal Diameter(mm)

 and Connection method

4,6,10,15,20,25,32,40  (tread connection)

15,20,25,32,40  (tread and flange connection)

50,65,80,100,125,150,200  ( flange connection)

Accuracy Class

Regular accuracy ±1%R, ±0.5%R,

Highest accuracy ±0.2% R

Measurement Range Rate

1:10,1:15,1:20

Instrument material

304 stainless steel; 316L stainless   steel; etc.

Medium Temperature(℃)

-20 ~   +120 ℃

Ambient Conditions

Temperature:-10~+55℃,

Relative Humidity: 5%~90%

Atmosphere Pressure:86~106Kpa

Signal Output

Sensor: pulse frequency signal,

low level≤0.8V

high level≥8V.

Transmitter: current signal

             4~20mA DC

             two wires

Supply Power

Sensor: +12V DC, +24V DC (option)

Transducer: +24V DC

Scene display type meter: 3.2V Lithium   cell

Signal Transmission Line

STVPV 3×0.3 (three wires), 2×0.3(two wires)

Transmission Distance

≤1000m

Signal Line Interface

Internal thread M20×1.5

Explode-proof Class

ExdIIBT6

Protection Class

IP65


Model Selection

Model

Explanation

LWGY-  □/  □/   □/  □/  □/  □/  □

 

 

 

DN

(mm)

 

 

 

 

4







4mm,   normal flow range0.04-0.25m3/h,wide flow range0.04-0.4m3/h

6

6mm,   normal flow range0.1-0.6m3/h,wide flow range0.06-0.6m3/h

10

10mm,   normal flow range0.2-1.2m3/h,wide flow range0.15-1.5m3/h

15

15mm   normal flow range0.6-6m3/h,wide flow range0.4-8m3/h

20

20mm   normal flow range0.8-8m3/h,wide flow range0.4-8m3/h

25

25mm   normal flow range1-10m3/h,wide flow range0.5-10m3/h

32

32mm   normal flow range1.5-15m3/h,wide flow range0.8-15m3/h

40

40mm   normal flow range2-20m3/h,wide flow range1-20m3/h

50

50mm   normal flow range4-40m3/h,wide flow range2-40m3/h

65

65mm   normal flow range7-70m3/h,wide flow range4-70m3/h

80

80mm   normal flow range10-100m3/h,wide flow range5-100m3/h

100

100mm   normal flow range20-200m3/h,wide flow range10-200m3/h

125

125mm   normal flow range25-250m3/h,wide flow range13-250m3/h

150

150mm   normal flow range30-300m3/h,wide flow range15-300m3/h

200

200mm   normal flow range80-800m3/h,wide flow range40-800m3/h

 

 

Type

 

N

Basic   type, +12Vsupply power,  pulse   output,  high level≥l8V,  low level≤0.8V

A

4—20mA   two wires current output, remote transmitting type.

B

Battery   supply power, scene display type.

C

scene   display/4—20m A two wires current output

C1

Scene   display/ RS485 communication protocol

C2

Scene   display /HART communication protocol


Accuracyclass

05





Accuracy   class 0.5

10

Accuracy   class 1.0

Measurement   range

mark

W




Wide   flow range turbine

S

Standard   measurement range turbine

Materials

S

304   Stainless steel

L

316(L)   Stainless steel

Explosion-proof

N

No   mark, non-explosion-proof

E

Explosion-proof(ExdIIBT6)

Pressure class

N

Normal   (reference to picture before)

H(x)

High   pressure (reference to picture before)


  • Easy install,simple structure.

  • High resolution and fast response time; 5 to 50 sec

  • Wide temperature range; -4 ~ 230 °F (-20 ~ 110 °C)

  • Pressures can stand up to 3,600 psig (250 bars) with using special high-pressure flanges

  • Easily cleaned; designed to flush particulates through the meter with the fluid media

  • Factory calibrated
    Battery-powered display available

  • 4~20mA, RS-485 and HART communicaitons available

  • Use stainless steel to improve durability and minimize maintenance

LWGY series turbine flow meter is a kind of intelligent integration by using the latest international digital integrated technology and according to the actual needs of domestic industrial automatic control research and development of a new generation of high quality intelligent instrument.Piezoelectric crystals as detecting element stress testing new type intelligent turbine flow meter.

 

This instrument has the range than wide, high precision, small pressure loss, good medium generality, and the flow rate is proportional to the pulse output, current signal, the RS - 485 communication, and computer combination conveniently.This Instrument has the characteristics of simple structure, high universality and high stability, respectively, are two kinds of active, passive, passive type does not need outer power supply built-in 3.6 V batteries, battery life more than three years.

 

The liquid crystal display meter, and instantaneous flow rate and flow accumulated, real-time temperature and pressure in real time.Intelligent turbine flow meter can through internal procedure, multi-point linear compensation for traffic signal, through the intelligent flow meter multi-point linear compensation, ensure accuracy of flow meter range segment at each point.


Aquaculture

Agriculture

Food & Beverage

Municipal Drinking Water

Wastewater

Power Generation

Marine

Life Sciences & Medical

Pulp & Paper

Oil & Gas

Mining Minerals & Metals

Hits: 【Print】